TES Hub

Thermal Energy Storage explained:
hot, cold, physics & common myths

Roughly half of all energy used in the world goes into making heat, and air conditioning is the fastest-growing strain on city power grids. Thermal Energy Storage (TES) stores heat or cold directly inside everyday materials like sand, brick, water, or ice. You do not need a physics degree to follow how it works. Keep one thing in mind: storing heat is very different from storing electricity.

HOT STORAGE · 100°C TO 2,000°C POWER IN ~98% HEAT Sand / Brick / Salt Hot Core · 600°C+ 80-95% HEAT OUT
COLD STORAGE · -40°C TO +7°C CHILLER 2.5-5x COLD Ice Balls / Brine / PCM Ice Bank · 0°C to -20°C PEAK SHIFT COOL OUT

1. Both sides of thermal storage: hot & cold

When people hear "thermal battery", they usually picture a glowing silo of hot sand or bricks. Thermal storage also works in the other direction. It can mean storing heat above room temperature, or storing cold below room temperature. Both follow the same playbook: buy cheap or surplus power now, bank the temperature difference inside an insulated box, and use it later when power is expensive.

Hot Storage · Above Room Temp

Heat batteries (50°C to 2,000°C+)

Turns cheap night-time electricity, extra solar or wind power, or factory waste heat into stored warmth for hot water, food drying, steam, and town heating pipes.

  • Home & hot water (50°C to 100°C): Insulated hot water tanks and compact home heat packs (phase-change materials).
  • Factory drying & town heating (100°C to 600°C): Sand, crushed rock, concrete blocks, and molten salt for drying tea/coffee, textiles, and heating buildings.
  • Heavy industry (600°C to 2,000°C+): Kiln bricks, solid carbon blocks, and liquid tin for high-pressure steam or glowing-heat power cells (TPV).
Cold Storage · Below Room Temp

Ice, chilled water & deep-freeze packs (-40°C to +10°C)

Runs cooling machines at night (when electricity is cheaper and cooler outdoor air lets chillers work more easily) or on midday solar panels, then melts stored ice to cool buildings during peak afternoon heat.

  • Chilled water (4°C to 7°C): Big insulated water tanks for campuses and district cooling. Simple, though the tanks take up a lot of space.
  • Ice tanks (0°C): Sealed ice balls (like Cryogel, commercial since 1989), ice frozen around coils, modular ice bricks, and ice blocks sitting in cold brine.
  • Deep-freeze packs (-40°C to -5°C): Special freezing packs (eutectic PCMs) inside frozen-food warehouses and vaccine trucks so compressors can switch off during peak tariff hours.

2. How thermal batteries hold energy: three ways

Every thermal battery on the market uses one (or a mix) of three physical tricks. Each card explains the idea first, then shows the short formula behind it.

1. Heating up or cooling down (sensible heat)

Just like a cast-iron pan staying hot after you turn off the stove. You heat up a solid or liquid without melting it. More weight (\(m\)), better heat-holding material (\(c_p\)), and a bigger temperature jump (\(\Delta T\)) mean more stored energy.

$$Q = m \cdot c_p \cdot \Delta T$$

Used in: Sand, kiln brick, crushed rock, concrete, water, molten salt, carbon blocks.

2. Melting or freezing (latent heat / PCM)

Think of ice cubes keeping a drink cold right at 0°C until every cube melts. Freezing 1 kg of water into ice packs away 334 kJ of cold, which equals cooling that same water by 80°C without freezing it. Materials picked for their melting point are called Phase Change Materials (PCMs).

$$Q = m \cdot L$$

Used in: Water/ice, salt-water mixes, waxes, special metal alloy blocks.

3. Reversible chemical mix (thermochemical)

Heat is used to split two ingredients apart (for example, drying moisture out of a salt). Once split, both parts can sit at room temperature for months without leaking heat. Bring them back together and the stored warmth comes right back out.

$$Q = n \cdot \Delta H_{\text{rxn}}$$

Used in: Salt hydrates, zeolites, lime/metal-oxide reactors. Still mostly in pilot stage.

MethodTypical Temp RangeSpace NeededHeat Leak Over TimeHow Proven Today
Heating / Cooling (Sensible)50°C to 2,000°CMedium to large1% to 5% per day (less in big silos)TRL 7 to 9 (commercial & proven)
Melting / Freezing (Latent PCM)-40°C to +700°CCompact for its temp windowLow (close to room temp)TRL 8 to 9 (ice proven since 1980s)
Chemical Split (Thermochemical)40°C to 1,500°CSmallest in theoryAlmost zero while separatedTRL 4 to 7 (early pilots)

3. Three bigger systems in the market: CSP, PTES & TPV

Simple heat and ice batteries just charge from grid power and give back heat or cold. When you browse the Global TES Market Landscape, you will also see three acronyms built to either capture sunlight directly or turn stored heat back into electricity. Here is what each one means in plain English.

TANK MIRRORS → HOT RECEIVER → 24/7 HEAT OR STEAM CSP + TES · Mirrors + Heat Tank

Concentrated solar power + storage (CSP + TES)

Instead of turning sunlight into electricity with regular solar panels, fields of mirrors focus sunlight onto a receiver to heat molten salt or hot rocks directly. That heat sits in an insulated tank so a factory gets 24/7 steam or a power plant keeps running all night after sunset.

Examples: Exowatt, GlassPoint, Cosin Solar, Synhelion.

COLD HOT PUMP ENGINE CHARGE HOT + COLD → REVERSE FOR POWER PTES · Heat Pump + Turbine Loop

Pumped thermal energy storage (PTES)

Also called a "Carnot battery". Think of a giant fridge and a heat engine working back-to-back. When power is cheap, a heat pump pulls heat out of a cold tank and pushes it into a hot tank (making one side freezing and the other scorching hot). Later, heat flows back through a turbine to make electricity again, aiming for ~50% to 65% back.

Examples: Malta Inc., Stiesdal, Echogen, Everllence.

1,500°C+ GLOW POWER WHITE-HOT BLOCK → LIGHT → SOLID-STATE CELLS TPV · Glowing-Heat Solar Cells

Thermophotovoltaics (TPV)

Heat a solid carbon or graphite block past 1,500°C until it glows white-hot like the inside of a furnace. Instead of boiling water to spin a noisy steam turbine, special solar cells sit right next to the glow and turn that bright light straight back into electricity with zero moving parts.

Examples: Antora Energy, Fourth Power.

4. Six common myths about thermal batteries

Startup pitches and viral videos often mix up thermal batteries with regular electric batteries. These six mix-ups come up the most.

Myth 1

"1 unit of stored heat is the same as 1 unit of stored electricity"

Reality: Electricity (\(\text{kWh}_e\)) is flexible energy that can run laptops, motors, chillers, or heaters. Heat (\(\text{kWh}_{\text{th}}\)) is tied to temperature and mostly just heats things up. Comparing a thermal tank at roughly $30 per kWh against a lithium battery pack at roughly $150 per kWh only works if your customer actually wants heat or cold. If they want electricity back, you lose a big chunk during conversion and have to buy an engine or generator too.

Myth 2

"Store cheap daytime solar in sand, then turn it back into electricity at night"

Reality: Turning electricity into heat is nearly 98% efficient. Going backwards from 500°C to 600°C heat into electricity runs into a hard rule of physics called the Carnot limit (\(\eta_{\text{Carnot}} = 1 - T_c / T_h\) in Kelvin). At 600°C on a 25°C day, nature caps you at 66%, and real turbines or engines only give back roughly 25% to 35% of the electricity you put in. About two-thirds escapes as waste heat.

That is why startups chasing grid power from heat either superheat carbon or liquid tin past 1,500°C and read the glow with special solar cells (TPV, aiming for ~35% to 45% back), or use heat-pump storage loops (PTES, aiming for ~50% to 65% back).

Myth 3

"Thermal batteries will replace lithium-ion batteries"

Reality: They do different jobs. Lithium-ion gives back 85% to 90% of the electricity you put in and reacts in milliseconds, so it stays the king of cars, electronics, and 1 to 6 hour power backup. Thermal storage wins when factories need steam or hot air, when buildings need afternoon cooling, or when you need cheap multi-day storage.

Myth 4

"Thermal storage is brand-new, unproven lab tech"

Reality: Cold thermal storage has been running reliably for more than 35 years. Cryogel launched its sealed HDPE Ice Balls back in 1989, and systems from Cryogel and CALMAC (now Trane IceBank) have cooled large buildings since the 1980s and 1990s. Home brick storage heaters go back to the 1950s. What is newer is giant, grid-connected high-heat silos built to soak up cheap wind and solar power.

Myth 5

"A small home sand battery holds heat just as well as a town-sized silo"

Reality: Stored heat depends on inside volume (\(L^3\)), while heat leaks out through the outer walls (\(L^2\)). My own 20 kg bench test, Sand Battery V0, cools down in hours. A giant 100 MWh town silo loses less than 1% per day. That is why small home heat batteries use lower-temperature hot water or PCM packs instead of 600°C sand.

Myth 6

"All ice storage tanks work the same way"

Reality: Water expands about 9% when it turns to ice, and every cooling system handles that push differently. Cryogel seals water inside 4-inch plastic balls molded with 16 dimples that flex outward as the ice grows and pull back in when it melts. Ice-on-coil tanks freeze ice around pipes submerged in an open tank. Block systems like I.C.E. Battery V1 freeze removable moulds in a -20°C saltwater bath. Each trades off space, freeze speed, piping, and upkeep.

What you actually get back (by use case)

SetupIn → OutTypical Real-World ReturnBest Fit
Direct Heating (Power-to-Heat)Electricity → Heat80% to 95% back as heat (heaters ~98%)Factory drying, steam, town heating, hot water
Cold Storage (Power-to-Cooling)Electricity → Cold2.5x to 5x cooling per unit of power (COP)Office A/C peak shaving, airports, cold warehouses
Medium-Temp Heat-to-Power (500-600°C)Electricity → Heat → Electricity25% to 35% back as electricityRarely pays off for power alone; better if you also use the waste heat
Ultra-Hot Heat-to-Power (1,500°C+ TPV)Electricity → Heat → Electricity35% to 45% target back as electricityMulti-day backup or combined heat + power
Heat-Pump Storage (PTES / Carnot)Electricity → Hot+Cold → Electricity50% to 65% target back as electricityLong-duration (8 to 100+ hr) grid storage
Lithium-Ion (For Comparison)Electricity → Chemical → Electricity85% to 90% back as electricityShort-duration (1 to 6 hr) grid power, EVs, backup

5. Try it yourself: why turning heat back into electricity wastes energy

Slide the storage temperature below to see what happens to 100 units of electricity when you use it directly as heat versus trying to turn it back into electricity through an engine or glowing-heat cell.

Sand, crushed rock, concrete, or molten salt range
600°C
PATH A · USE IT AS HEAT (100 kWh IN) 100 kWh(e) 92 kWh(th) Heat PATH B · TURN HEAT BACK INTO ELECTRICITY (100 kWh IN) 100 kWh(e) Heat Engine Carnot max 66% 66 kWh Waste Heat 34 kWh(e) Power
Physics Ceiling (Carnot limit at 25°C outside) 66%
Real-World Electricity Back Out (~half of physics ceiling) 34%
Direct Heat Out (no conversion back to electricity) 92%

6. Frequently asked questions

What is Thermal Energy Storage (TES) in plain terms?

It is a giant thermos for heat or cold. You heat up something cheap like sand, brick, or water (or freeze ice) when electricity is cheap or the sun is shining, keep it inside thick insulation, and draw that heat or cold out hours or days later when a home, building, or factory needs it.

Is storing heat the same as storing electricity?

No. Electricity is flexible energy (kWh(e)) that can run phones, motors, lights, or heaters. Heat and cold are thermal energy (kWh(th)) tied to temperature. Turning 1 unit of electricity into heat is easy (almost 100% turns into heat), and a chiller can move 2.5 to 5 units of cold for every 1 unit of power. Turning stored heat back into electricity is much harder and loses most of the energy as waste heat.

Why is turning stored heat back into electricity so inefficient?

Physics sets a hard ceiling called the Carnot limit, which depends on how hot the store is compared to the outside air (measured in Kelvin). A 600°C sand or salt tank in 25°C weather hits a 66% theoretical cap, and real steam turbines or engines only capture about half of that, leaving roughly 25% to 35% of the electricity you started with. That is why startups trying to make electricity from heat push temperatures past 1,500°C using glowing-heat solar cells (TPV) or use heat-pump storage loops (PTES).

When does a thermal battery beat a lithium-ion battery?

Whenever you actually want heat or cold at the end. Factories drying food, making steam, heating towns, or cooling office towers do not need electricity at the final step. Storing cheap solar or night-time power straight as heat (80% to 95% efficiency) or ice (2.5 to 5 units of cooling per unit of power) usually costs far less per kWh than a lithium-ion pack, and the hardware has no cycle wear to speak of.

When does lithium-ion beat thermal storage?

When you need electricity back out for 1 to 6 hours, such as electric cars, phone/home backup, and fast grid balancing. Lithium-ion gives back 85% to 90% of the electricity you put in, which no pure heat-to-electricity engine can match today.

What are the three ways thermal batteries hold energy?

First, warming up or cooling down a material without melting it (sensible heat, like hot sand, brick, or water). Second, melting or freezing a material at a steady temperature (latent heat, like freezing water into ice or using wax/salt packs called PCMs). Third, reversible chemical reactions (thermochemical), where heat separates two ingredients that sit at room temperature without leaking heat until you mix them back together.

How long has commercial cold storage existed?

More than 35 years. Ice-ball tanks like Cryogel (launched in 1989 with dimpled plastic balls that flex as water expands 9% when freezing) and ice-coil tanks like CALMAC (now Trane IceBank, since the 1980s) have been shifting office and campus cooling loads to night-time power for decades.

Why do ice batteries use saltwater or glycol instead of plain water in the pipes?

Plain water freezes solid at 0°C, which would clog and burst the pipes before the ice tank finishes freezing. A chilled glycol mix or saltwater brine stays liquid down to -5°C to -21°C, so it can freeze the water inside the moulds or balls at night and carry cold out to the air-conditioning loop during the hot afternoon.

Why do huge sand silos hold heat for weeks while small prototypes cool down overnight?

The amount of heat you can store grows with the inside volume, while heat leaks out through the outside walls. Double every side of a box and you hold 8 times more heat with only 4 times more wall area. My own 20 kg bench test (Sand Battery V0) cools down in hours. A 100 MWh town-scale sand silo loses less than 1% of its heat per day.

What do Technology Readiness Levels (TRL 1 to 9) mean?

TRL is a simple 1-to-9 score for how proven a technology is. TRL 1 to 3 means lab science and bench tests. TRL 4 to 6 means working pilot hardware tested in real conditions. TRL 7 to 8 means first full-size commercial plants. TRL 9 means proven everyday commercial hardware running at many customer sites, like Cryogel ice balls or electric steam boilers. Read the full Technology Readiness Level (TRL) definition on Wikipedia →